BS-230 is a “CUTE”, multi-functional benchtop clinical chemistry analyzer with a throughput at 200 T/H, up to 400 T/H with ISE.Though with a compact size, it has achieved a host of advanced functions never before found on a like product in the market, making it an optimal chemistry solution for small laboratories and a back-up tool for mid-to-high end laboratories. BS-480 Chemistry Analyzer Enhanced Liquid System Precise sample and reagent aspiration Built in air bubble elimination prior to washing High pressure interior probe wash Carry-over.
- Parts
- Videos
- News
DESCRIPTION
A bench top, discrete and random access clinical chemistry analyzer with 200 tests per hourIt’s tailored for small laboratories (used as a main instrument); medium and big laboratories (used as a back-up instrument)
FORUMSView All (28)
Ask a New Question1Reply6 months ago | 6 months agoConnection with LIS error I try to connect with BS-200E via TCP/IP after I set up our LIS destinate IP/Port on the analyzer and connect successfully but I still didn't receive the result from our application (The send button is enable but I don't want to send manually) Please help me.Reply |
-m.krawczyk 7 months ago | 7 months agoDownloading sample from LIS to analyzer via tcp Hello.I am working on LIS and have a problem with sending samples to analyzer. Receiving result works well, but sending samples.. well not at all. Communication seems good i received ACK^Q03 every sent sample, but they don't register in software.So I have some question:1. What about DSP - 29 filed where tests number are set. How it should look when I use 'Code on LIS' mapping? It should contains only number? Like ex. DSP|29||1^^^||| 2. Where can I find 'ItemID.ini' file which is mention in 'Host Interface Manual'? It doesn't appear in installation folder.3. Is there analyzer (BS-200) is required to register samples in software? Because manually you can, maybe there is restriction for downloading samples.4. There is any chance to use 'Code on LIS' mapping instead of numbers fixed? Ex:DSP|29||1^^^||| -> DSP|29||^AMY^^||| Reply |
1Reply8 months ago | 8 months agoProblem of assigning sample position using LIS in Mindray BS-200 I have developed an App that connects my LIS to analyzer Mindray BS-200 using hl7 protocol via TCP. Everything worked correctly, the results are received from the analyzer and the requests of test are sent successfully to analyzer. The only problem I have met is that, when i send a request of test to analyzer, the sample position is not assigned, it still be blank. Consequently, the process of analyzing can not be launched; since the position field is empty.I would appreciate any advise for solving this problem.Reply |
DOCUMENTS / MANUALSView All
FEATURES
- 200 tests per hour, up to 330 tests per hour with ISE
- Up to 40 positions for samples and reagents respectively
- Automatic probe cleaning, liquid level detection, collision protection
- 8 wavelengths
- Refrigerated reagent compartment
- Bi-directional LIS interface
SPECIFICATIONS
Wavelength Range | 340 to 670 nm |
One moment please..
Add Clinical Chemistry Analyzer to My Bench28 Results
1 ReplyI try to connect with BS-200E via TCP/IP after I set up our LIS destinate IP/Port on the analyzer and connect successfully but I still didn't receive the result from our application (The send button is enable but I don't want to send manually) Please help me.
1 ReplyHello.I am working on LIS and have a problem with sending samples to analyzer. Receiving result works well, but sending samples.. well not at all. Communication seems good i received ACK^Q03 every sent sample, but they don't register in software.So I have some question:1. What about DSP - 29 filed where tests number are set. How it should look when I use 'Code on LIS' mapping? It should contains only number? Like ex. DSP|29||1^^^||| 2. Where can I find 'ItemID.ini' file which is mention in 'Host Interface Manual'? It doesn't appear in installation folder.3. Is there analyzer (BS-200) is required to register samples in software? Because manually you can, maybe there is restriction for downloading samples.4. There is any chance to use 'Code on LIS' mapping instead of numbers fixed? Ex:DSP|29||1^^^||| -> DSP|29||^AMY^^|||
1 ReplyI have developed an App that connects my LIS to analyzer Mindray BS-200 using hl7 protocol via TCP. Everything worked correctly, the results are received from the analyzer and the requests of test are sent successfully to analyzer. The only problem I have met is that, when i send a request of test to analyzer, the sample position is not assigned, it still be blank. Consequently, the process of analyzing can not be launched; since the position field is empty.I would appreciate any advise for solving this problem.
1 Replyhow i solve this for continue
0 RepliesMy bs200 shows reaction disk temperature is 44c .but i measure it was about 32c. And software starting time also it show 44c. But room temperature about 32c. Whats problem.? When i remove the reaction disk cover and top heater and cuvets hanging disk temperature down as 37c. Free manuals downloads. Pls help me to solve this.
Mindray Bs 200e Service Manual Pdf
0 RepliesMy bs200 shows reaction disk temperature is 44c .but i measure it was about 32c. And software starting time also it show 44c. But room temperature about 32c. Whats problem.? When i remove the reaction disk cover and top heater and cuvets hanging disk temperature down as 37c. Pls help me to solve this.
1 ReplyOur equipment is no longer reading the sample bar code. Unbelievably the problem began after the technician visit for periodic maintenance. Any idea how to solve the problem? The responsible company here in Brazil is not being able to solve. Thank you!
2 RepliesHi all,I try to connect with BS-200E via TCP/IP LAN cable after I set up our LIS destinate (IP/Port) on the analyzer and start Connect successfully but I still cannot transfer the result from our application (The Send button is enabled but we don't receive any HL7 message)Please help me.
User Manual Pdf Download
1 ReplyWhen i like configure the LIS in the software the system showme the error exist conflict with LIS. Any suggestion?I don't disable LIS, change IP o any other change
Mindray Bs 200e Manual
1 ReplyWhen my LIS receive message with type ORU^R01 (contains the Sample result OBX,OBR) it respond s with ACK^R01 this cause the mindray bs-200 software to shutdown!!! I couldn't explain that since I followed the instructions in the manual, any help will be nice , thank you in advance